welfare units.Manufactured by Trime Italy and Trime UK,
HogPower has powered
for nearly 40 years - continuously advancing to deliver exceptional sustainability, performance, and reliability.

6kva 3000rpm air cooled
Available in Standard and Fusion Pulse Welfare units
Manual start
Factory set 3hr run time

9.8kva 1500rpm water cooled
Available in Standard and Fusion Pulse Welfare units
Manual start
Factory set 3hr run time

6kva 3000rpm air cooled
Available in Fusion Li Welfare units
Auto start battery sensor
Auto start required to power kettle and heat water will run for 15 mins

9.8kva 1500rpm water cooled
Available in Fusion Li Welfare units
Auto start battery sensor
Auto start required to power kettle and heat water will run for 15 mins
By using our interactive calculator you can see where real savings can be made to your budget and how you can gain significant reductions in your Carbon (measured as CO2e) emissions which will help you offset the environmental impact of your welfare accommodation requirements.
View calculatorSpecified in groundog® Fusion Li units, HogPowerLi60 and HogPowerLi98 utilise a highly efficient 130amp power AGM battery, charged via the intelligent solar power system built in controller, backed up by an on-board power silenced generator – ensuring optimum performance is maintained when in use and unmanned.
This allows the LED lighting, diesel powered heating system, microwave and inverter powered electrical sockets to be operational and also dispenses warm water in toilet and canteen – all without the need for the generator to be running.*
* The generator only needs to be running to power the microwave, kettle & hot water system
ECO hybrid power providing sustainable welfare accommodation.
Specified in groundog® Fusion Pulse units, HogPowerS60 and HogPowerS98 utilise a highly efficient 130amp power AGM battery, charged via the intelligent solar power system built in controller, backed up by an on-board power silenced generator – ensuring optimum performance is maintained when in use and unmanned.
This allows the LED lighting, diesel powered heating system and inverter powered electrical sockets to be operational and also dispenses warm water in toilet and canteen – all without the need for the generator to be running.*
* The generator only needs to be running to power the microwave, kettle & hot water system
ECO hybrid power providing sustainable welfare accommodation.

6kVA 230V AC Aux Power
|
plug and play power to meet even
the most demanding site Welfare units
applications
|
Diesel engine - Kohler Stage V
|
robust and easy to use with
world class performance
|
Mecc Alte alternator
|
heavy duty with proven reliability
|
HVO (Hydrotreated Vegetable Oil) fuel
approved
|
suitable to run on diesel, HVO
or a mixture of both fuels
|

9.8kVA 230V AC Aux Power
|
plug and play power to meet even
the most demanding site Welfare units
applications
|
Diesel engine - Kubota Stage V
|
robust and easy to use with
world class performance
|
Zanardi alternator
|
heavy duty with proven reliability
|
HVO (Hydrotreated Vegetable Oil) fuel
approved
|
suitable to run on diesel, HVO
or a mixture of both fuels
|

6kVA 230V AC Aux Power
|
plug and play power to meet even
the most demanding site Welfare units
applications
|
Diesel engine - Kohler Stage V
|
robust and easy to use with
world class performance
|
Mecc Alte alternator
|
heavy duty with proven reliability
|
HVO (Hydrotreated Vegetable Oil) fuel
approved
|
suitable to run on diesel, HVO
or a mixture of both fuels
|

9.8kVA 230V AC Aux Power
|
plug and play power to meet even
the most demanding site Welfare units
applications
|
Diesel engine - Kubota Stage V
|
robust and easy to use with
world class performance
|
Zanardi alternator
|
heavy duty with proven reliability
|
HVO (Hydrotreated Vegetable Oil) fuel
approved
|
suitable to run on diesel, HVO
or a mixture of both fuels
|
| Alternator Synchronous type |
M E ECC ALT 6S 2k0VWA 121300/V2 |
| Single phase power (110V) | N/A |
| Single phase power (230V) | 6kVA |
| Battery (not included) | 12V |
| Frequency | 50 Hz |
| Insulation class | H |
| Mechanical protection - IP | 23 |
| Noise level | 82Lwa 57 dBa@7m |
| Litres per hour | 6-10L |
| Co2e emissions per hour | 4Kg |
| Engine make | Kohler |
| Engine type | KD15/440 |
| Fuel | Diesel / HVO |
| N° cylinders | 1 |
| Power | 10 HP |
| Engine speed | 3000 rpm |
| Cooling | Air |
| Oil capacity | 1.5L |
| Starting system | Electric / Remote |
| Fuel consumption | 250 gr/kwh |
| Length (mm) | 825 |
| Width (mm) | 520 |
| Height (mm) | 660 |
| Dry weight - no fuel (Kg) | 167 |
| Wet weight - full fuel (Kg) | TBA |
| Alternator Synchronous type |
ZANARDI PE28 2VS/4 |
| Single phase power (110V) | N/A |
| Single phase power (230V) | 9.8kVA |
| Battery (not included) | 12V 44 Ah |
| Frequency | 50 Hz |
| Insulation class | H |
| Mechanical protection - IP | 23 |
| Noise level | 79Lwa 54 dBa@7m |
| Litres per hour | 6-10L |
| Co2e emissions per hour | 5Kg |
| Engine make | Kubota |
| Engine type | D1105 |
| Fuel | Diesel / HVO |
| N° cylinders | 3 |
| Power | 13.7 HP |
| Engine speed | 1500 rpm |
| Cooling | Water |
| Oil capacity | 5.11L |
| Starting system | Electric / Remote |
| Fuel consumption | 265 gr/kwh |
| Length (mm) | 1100 |
| Width (mm) | 790 |
| Height (mm) | 1470 |
| Dry weight - no fuel (Kg) | 536 |
| Wet weight - full fuel (Kg) | TBA |
| Alternator Synchronous type |
M E ECC ALT 6S 2k0VWA 121300/V2 |
| Single phase power (110V) | N/A |
| Single phase power (230V) | 6kVA |
| Battery (not included) | 12V |
| Frequency | 50 Hz |
| Insulation class | H |
| Mechanical protection - IP | 23 |
| Noise level | 82Lwa 57 dBa@7m |
| Litres per hour | 6-10L |
| Co2e emissions per hour | 4Kg |
| Engine make | Kohler |
| Engine type | KD15/440 |
| Fuel | Diesel / HVO |
| N° cylinders | 1 |
| Power | 10 HP |
| Engine speed | 3000 rpm |
| Cooling | Air |
| Oil capacity | 1.5L |
| Starting system | Electric / Remote |
| Fuel consumption | 250 gr/kwh |
| Length (mm) | 825 |
| Width (mm) | 520 |
| Height (mm) | 660 |
| Dry weight - no fuel (Kg) | 167 |
| Wet weight - full fuel (Kg) | TBA |
| Alternator Synchronous type |
ZANARDI PE28 2VS/4 |
| Single phase power (110V) | N/A |
| Single phase power (230V) | 9.8kVA |
| Battery (not included) | 12V 44 Ah |
| Frequency | 50 Hz |
| Insulation class | H |
| Mechanical protection - IP | 23 |
| Noise level | 79Lwa 54 dBa@7m |
| Litres per hour | 6-10L |
| Co2e emissions per hour | 5Kg |
| Engine make | Kubota |
| Engine type | D1105 |
| Fuel | Diesel / HVO |
| N° cylinders | 3 |
| Power | 13.7 HP |
| Engine speed | 1500 rpm |
| Cooling | Water |
| Oil capacity | 5.11L |
| Starting system | Electric / Remote |
| Fuel consumption | 265 gr/kwh |
| Length (mm) | 1100 |
| Width (mm) | 790 |
| Height (mm) | 1470 |
| Dry weight - no fuel (Kg) | 536 |
| Wet weight - full fuel (Kg) | TBA |
Fitted as standard in Groundhog welfare units, FUELACTIVE has revolutionised one of the most overlooked components in engine performance - the fuel pick-up pipe. The patented technology replaces conventional fuel pick-up systems with an innovative, floating design that ensures only clean fuel is drawn from the top of the fuel level, avoiding the contaminated fuel that settles at the bottom.
By maintaining clean combustion, engines run more efficiently, reducing fuel use and CO2 emissions while preserving factory-level performance throughout their life cycle.

Watch how the FUELACTIVE technology filters contaminated fuel in the video below